Skip to content
English
  • There are no suggestions because the search field is empty.

S400 Z-Axis Limit Switch Function

In Hardware Diagnostics Mode (HD), how do the Z-axis Table Limit Switch Function.

 
Enter Diagnostics Mode by turning on the machine and when it starts to initialize pressing the HD icon that appears.
 
The Z-axis table will NOT move if the limit switch is pressed or stuck in the pressed position - This also depends on which one - For example if the top limit switch is pressed the table will not move up however it will move down - 
 
If the down limit switch is pressed the table will not move down but will move up assuming the top sensor is not pressed
 
And if BOTH are stuck in the pressed position - the table will NOT move up or down. 
 
Video Link Click Below:
https://gccanas.synology.me:5001/d/s/16HxR8NVewvolxpQPkT9MEaxnNpiSKLt/TIILKYyNDPni-8bot4EzVmpH9ssSlg0u-Gr5AngNI1Aw
 
As for bypassing - I would follow the switch to the connector - Not to the mainboard - 
 
Disconnect at the connection and use a Jumper to bypass.